Thermostats

Industrial thermostats for electric heat tracing

29 variants · 2 product lines

Not sure which control system to choose?

Tell us how many circuits you need to supply and how control should work: thermostat, controller or integration with a DCS/BMS. We will select the controls and design the control panel.

Help me select the controls

Technical specification

Mechanical thermostats

SymbolDescriptionManufacturer no.Datasheets
T-M-20-S/+0+120C/EXMechanical line-sensing thermostat with limiter, ATEX, setpoint range 0°C to +120°C1244-016536No PDF
RAYSTAT-EX-02Mechanical surface-sensing thermostat, liquid-filled capillary sensor, setpoint range -4°C to +163°C404385-000
T-M-10-S/0+50CMechanical line-sensing thermostat, setpoint range 0°C to +50°C105336-000No PDF
T-M-20-S/+0+200C/EXMechanical thermostat with limiter (0-200°C), Ex1244-013410No PDF
T-M-20-S/+50+300C/EXMechanical thermostat with limiter (50-300°C), Ex1244-013411No PDF
T-M-10-S/0+200CMechanical line-sensing thermostat, setpoint range 0°C to +200°C337388-000No PDF
T-M-10-S/+50+300CMechanical line-sensing thermostat, setpoint range +50°C to +300°C607672-000No PDF
T-M-20-S/0+100CMechanical line-sensing thermostat and limiter (0-100°C)1244-022642No PDF
T-M-20-S/0+200CMechanical line-sensing thermostat and limiter (0-200°C)1244-022643No PDF
T-M-20-S/+50+300CMechanical line-sensing thermostat and limiter (50-300°C)1244-022644No PDF

Electronic thermostats

SymbolDescriptionManufacturer no.Datasheets
AT-TS-13Line- or ambient-sensing thermostat, -5°C to +15°C, PTC KTY 83-110 sensor728129-000
RAYSTAT-ECO-10UnavailableElectronic thermostat, PASC algorithm145232-000No PDF
RAYSTAT-CONTROL-10UnavailableElectronic line-sensing controller (0/+120°C)828810-000No PDF
AT-TS-14Line- or ambient-sensing thermostat, 0°C to +120°C, PTC KTY 83-110 sensor648945-000
ETRON- T100Electronic thermostat - DIN rail mountable1200-001269No PDF
RAYSTAT-V5Electronic controller for Raychem heating cables, temperature sensor included1244-022440No PDF
ELEXANT 450cController for 2 pipe frost protection heating zones, DIN rail mounting in a control panel1244-021970
ETS-05-L2-EElectronic line-sensing thermostat, ATEX (199°C)1244-014367
ETS-05-H2-EElectronic line-sensing thermostat, ATEX (499°C)1244-014368
ETS-05-A2-EElectronic ambient-sensing thermostat (0-49°C), 240 Vac, ATEX1244-022311
See all 19 variants (9 more)

A thermostat for heating cable - why and when?

A thermostat switches the heating cable on only when the temperature falls below the set point and switches it off once the installation is safe. That means lower energy consumption, longer cable life and control over the medium temperature. In some hazardous area applications a thermostat or temperature limiter is required so that the cable surface does not exceed the temperature class of the area.

Mechanical or electronic thermostat?

  • Mechanical (capillary) thermostats - a simple, rugged design with a capillary sensor and no electronics. They work well for frost protection and in harsh conditions, including Ex versions.
  • Electronic thermostats - Pt100 sensor, precise set point, display and alarms. For process temperature maintenance and wherever you need to see how the system is running.
  • Controllers and heat tracing control panels - when there are many circuits, or when monitoring, reporting or DCS/BMS integration is needed.

Pipe-mounted or ambient thermostat?

A pipe-mounted thermostat has its sensor fixed to the pipe or tank and controls the medium temperature - the solution for process temperature maintenance. An ambient thermostat measures the air temperature and switches on the whole heating system when it gets cold - a simple and economical way to provide frost protection for many circuits at once. We often combine both: ambient sensing for frost protection and pipe sensors where the process matters.

Thermostats for hazardous areas (Ex)

In refineries, chemical and petrochemical plants we use Ex-rated thermostats and Pt100 temperature sensors, selected for the zone and temperature class. We design the controls together with the heating cable and accessories as one coherent system.

Control selected together with the whole system

We select the thermostat for the cable, the type of installation and how it operates - not in isolation. We provide cable and control selection, circuit design, supply, installation and commissioning, and once the system is running we carry out inspections before the winter season.

Not sure which control system to choose?

Tell us how many circuits you need to supply and how control should work: thermostat, controller or integration with a DCS/BMS. We will select the controls and design the control panel.

Help me select the controls

Frequently asked questions

Does a heating cable need a thermostat?

+

In most installations, yes. A thermostat switches the heating on only when the temperature falls below the set point, which reduces energy consumption and extends cable life. In hazardous areas temperature control may be required so that the cable surface does not exceed the temperature class of the area.

Mechanical or electronic thermostat - which should I choose?

+

For simple frost protection a mechanical (capillary) thermostat is usually enough. Where accuracy, alarms and visibility of operation matter, or for process temperature maintenance, we use an electronic thermostat with a Pt100 sensor, and for many circuits a controller or heat tracing control panel.

Will you select the thermostat together with the cable and the design?

+

Yes. We select the controls together with the heating cable, accessories and circuit layout, as one system. We handle selection, design, supply, installation and commissioning, followed by inspections before the winter season.