❄️ Winter campaign: Protect installations against frost.See details
Electronic thermostats

Electronic thermostats

Electronic thermostats is a product line in the thermostats category. 19 variants are available, including AT-TS-13, AT-TS-14, ETRON- T100, RAYSTAT-V5, ELEXANT 450c, ETS-05-L2-E, ETS-05-H2-E, ETS-05-A2-E. We will help you select the right type for your installation, prepare a quotation and take care of supply and installation.

19 variants in this line

Not sure which control system to choose?

Tell us how many circuits you need to supply and how control should work: thermostat, controller or integration with a DCS/BMS. We will select the controls and design the control panel.

Help me select the controls

Product types and technical specification

SymbolDescriptionManufacturer no.Datasheets
AT-TS-13Line- or ambient-sensing thermostat, -5°C to +15°C, PTC KTY 83-110 sensor728129-000
RAYSTAT-ECO-10UnavailableElectronic thermostat, PASC algorithm145232-000No PDF
RAYSTAT-CONTROL-10UnavailableElectronic line-sensing controller (0/+120°C)828810-000No PDF
AT-TS-14Line- or ambient-sensing thermostat, 0°C to +120°C, PTC KTY 83-110 sensor648945-000
ETRON- T100Electronic thermostat - DIN rail mountable1200-001269No PDF
RAYSTAT-V5Electronic controller for Raychem heating cables, temperature sensor included1244-022440No PDF
ELEXANT 450cController for 2 pipe frost protection heating zones, DIN rail mounting in a control panel1244-021970
ETS-05-L2-EElectronic line-sensing thermostat, ATEX (199°C)1244-014367
ETS-05-H2-EElectronic line-sensing thermostat, ATEX (499°C)1244-014368
ETS-05-A2-EElectronic ambient-sensing thermostat (0-49°C), 240 Vac, ATEX1244-022311
ETS-05-A2-E-AElectronic ambient-sensing thermostat with alarm relay, ATEX1244-022663
ETS-05-L2-EPElectronic line-sensing thermostat, ATEX (199°C), 240 V AC1244-017508
ETS-05-L2-EP-AElectronic line-sensing thermostat with alarm relay, earth plate, ATEX (199°C)1244-022669
ETS-05-H2-EPElectronic line-sensing thermostat, ATEX (499°C), 240 V AC1244-017509
ETS-05-H2-EP-AElectronic line-sensing thermostat with alarm relay, earth plate, ATEX (499°C)1244-022670
ETS-05-H2R-E-AElectronic line-sensing thermostat, ATEX (499°C), 277 VAC, alarm relay1244-022675
ETS-05-H2R-EP-AElectronic line-sensing thermostat with alarm relay, earth plate, ATEX (499°C), 277 V AC1244-022680
ETS-05-L1-JElectronic surface-sensing thermostat (0-199°C), 110 Vac, ATEX1244-015658
ETS-05-H1-JElectronic surface-sensing thermostat (0-499°C), 110 Vac, ATEX1244-015659

What electronic thermostats are used for

An electronic thermostat controls one or two heating circuits more precisely than a capillary thermostat: it has a smaller hysteresis, indicates cable status and sensor failure, and some versions provide an alarm contact to the BMS or DCS. It is used for pipe freeze protection and process temperature maintenance with self-regulating heating cables. ETS-05 versions operate in Zone 1, 2, 21 and 22, AT-TS models are intended for non-hazardous areas, and the Elexant 450c (IP20) is DIN-rail mounted in the control panel. For larger numbers of circuits and central monitoring, temperature controllers are the better choice.

Variants and product codes

  • AT-TS-13 (setpoint from -5°C to +15°C, freeze protection) and AT-TS-14 (from 0°C to +120°C) - IP65 enclosure for pipe or wall mounting, non-hazardous area.
  • ETS-05-L2-E (0-199°C), ETS-05-H2-E (0-499°C), ETS-05-A2-E (ambient sensor, 0-49°C) - ATEX/IECEx thermostats with Pt100 sensor.
  • ETS-05 suffixes: P - earth plate (e.g. ETS-05-L2-EP), A - alarm relay, 2R - 195-277 Vac supply, 1 - 110 Vac, J - certificate for Japan.
  • Elexant 450c - 2-circuit DIN-rail controller for the control panel, 4.3-inch touchscreen, PASC algorithm.
  • RAYSTAT-V5 and ETRON-T100 - other electronic thermostats in the range (ETRON-T100 for DIN-rail mounting).
  • RAYSTAT-ECO-10 and RAYSTAT-CONTROL-10 - discontinued models; we select a replacement from the current range.

Datasheet parameters

  • AT-TS-13/14: 230 Vac, 16 A/250 Vac contact, hysteresis 0.6-1 K, KTY 83-110 sensor on a 3 m lead (extendable to 100 m).
  • ETS-05: IP66, 32 A contact (resistive load), hysteresis approx. 3°C, ambient from -40°C to +60°C, class T5, configurable fail-safe mode on sensor failure.
  • Elexant 450c: outputs 2 x 4 A/230 Vac, setpoint 0-80°C (up to +245°C with the SM-PT100-2 module), -Modbus version with RS485.

Selection, installation and replacements

We select the thermostat for the area classification, process temperature, circuit current and sensing method (pipe or ambient), and where currents exceed the contact rating we design in a contactor. Field-mounted thermostats are fixed on SB-100, SB-101, SB-110, SB-111 or SB-130 mounting brackets. If RAYSTAT-ECO-10 or RAYSTAT-CONTROL-10 is installed on your site, describe the circuit via contact; more about replacing discontinued models is in the discontinued product replacements section.

Not sure which control system to choose?

Tell us how many circuits you need to supply and how control should work: thermostat, controller or integration with a DCS/BMS. We will select the controls and design the control panel.

Help me select the controls

Frequently asked questions

What is the difference between ETS-05-L2-E and ETS-05-L2-EP?

+

Both thermostats have a 0-199°C setpoint range and a 230 Vac supply. The letter P denotes the version with an earth plate. The suffix -A (e.g. ETS-05-L2-EP-A) denotes an additional alarm relay.

Can AT-TS-13 be used in an Ex area?

+

No. AT-TS-13 and AT-TS-14 are intended for non-hazardous areas. In Zones 1, 2, 21 and 22, ETS-05 thermostats with ATEX/IECEx certification are used.

RAYSTAT-CONTROL-10 is no longer available. What can replace it?

+

The model has been discontinued. We select a replacement individually from the current range, based on the temperature range, number of circuits, area classification and the alarms required in the existing installation.

View all