Heat tracing for data centres

A data centre has to run 24/7, even at −20°C. We protect cooling, water and fire protection systems against freezing, and driveways, roofs and gutters against snow and ice. We handle everything: from selection and design to installation, commissioning and servicing.

Data centres

Why a data centre needs heat tracing

IT equipment runs in air-conditioned halls, but much of the infrastructure that powers and cools it sits outdoors or in unheated areas. That is exactly where winter strikes:

  • A frozen cooling pipe means a risk of data halls overheating and servers shutting down in an emergency.
  • A frozen sprinkler or hydrant system leaves the facility without working fire protection.
  • An icy driveway cuts off access for service teams, fuel deliveries to the generators and emergency crews.
  • Icicles and ice dams on the roof endanger people, damage gutters, cause leaks and put rooftop equipment at risk.

Any of these situations can end in downtime, and in a data centre downtime means breached SLAs, contractual penalties and risk to customer data.

What we heat in data centres

  • Cooling and chilled water pipework: outdoor sections, dry cooler and chiller connections, rooftop installations and runs in unheated ducts.
  • Fire protection systems: sprinkler risers and mains, hydrants and fire water tanks in areas exposed to frost.
  • Water and drainage systems: service connections, condensate drains and downpipes routed outdoors.
  • Driveways, ramps and stairs: gate access, the unloading area, and yards by the generators and fuel stations.
  • Roofs, gutters and downpipes: de-icing systems that drain meltwater and prevent icicles from forming.

How we run the project

We take on the entire scope, so the investor and the general contractor have a single partner for electric heating:

Analysis and selection

Documentation review, site survey, power balance and selection of heating cables and control to suit site conditions.

Detailed design

Cable routes, distribution boards and supply circuits designed around the existing infrastructure and BMS.

Supply of materials

Certified Raychem (Chemelex) heating cables, control and accessories, delivered to site in line with the schedule.

Installation

Installation by our own team, including on a live facility, in line with operations and maintenance procedures.

Commissioning

Insulation resistance measurements, functional tests, control configuration and operator training.

As-built documentation

A complete set of documentation, test reports and circuit descriptions that makes operation and maintenance easier.

Inspections and servicing

Pre-winter inspections and a fast service response whenever the installation needs attention.

Reliability and lower energy costs

  • Self-regulating heating cables: they reduce their own output as it gets warmer, so the heating does not draw power unnecessarily.
  • Control and monitoring: thermostats and weather sensors switch the heating on only when there is a risk of frost or icing. Alarm signals can be connected to the BMS.
  • A power balance sized to the facility: we design the installation so that it does not needlessly load the power supply, which is the most valuable resource in a data centre.
  • Clear documentation: labelled circuits and cabinets make maintenance easier and faults quick to locate.

"A data centre cannot wait for the thaw. We design heating so that winter poses no risk to the facility and is not one more problem for the operations team to watch."

Frequently asked questions

Which systems in a data centre need electric heat tracing?

+

Most often these are outdoor sections of cooling and chilled water pipework, fire protection systems in unheated areas, water service connections and condensate drains, as well as driveways, ramps, roofs, gutters and downpipes. We define the scope after reviewing the documentation and carrying out a site survey.

Do you handle design and installation, or supply only?

+

We deliver the whole package: selection, design, supply of materials, installation, commissioning and servicing. If the general contractor carries out the installation, we can supply materials only, with technical selection and supervision.

Can you work in a live data centre?

+

Yes. We plan the work together with the operations and maintenance team, following site procedures, so as not to disrupt data centre operations.

Can the heating be integrated with the BMS?

+

Yes. Controllers and thermostats can report operating status and alarms to the building management system, so the operations team sees everything in one place.

How much does heat tracing cost for a data centre?

+

The cost depends on the length and type of the systems to be heated, the area of driveways and roofs, the control method and the scope of work. Once we receive the basic data, we will prepare a selection and a tailored quotation.

We will find the right solution for data centres

We usually prepare quotations within 24 hours. Talk to our specialists - we will advise free of charge and select a heat tracing system that fits the specific needs of your industry. Enquiries in English are welcome.

  • Free technical consultation
  • Power output and complete accessory selection
  • Backed by 30+ years of experience