
Mechanical thermostats
Mechanical thermostats is a product line in the thermostats category. 10 variants are available, including T-M-20-S/+0+120C/EX, RAYSTAT-EX-02, T-M-10-S/0+50C, T-M-20-S/+0+200C/EX, T-M-20-S/+50+300C/EX, T-M-10-S/0+200C, T-M-10-S/+50+300C, T-M-20-S/0+100C. We will help you select the right type for your installation, prepare a quotation and take care of supply and installation.
10 variants in this line
Not sure which control system to choose?
Tell us how many circuits you need to supply and how control should work: thermostat, controller or integration with a DCS/BMS. We will select the controls and design the control panel.
Product types and technical specification
| Symbol | Description | Manufacturer no. | Datasheets |
|---|---|---|---|
| T-M-20-S/+0+120C/EX | Mechanical line-sensing thermostat with limiter, ATEX, setpoint range 0°C to +120°C | 1244-016536 | No datasheetNo PDF |
| RAYSTAT-EX-02 | Mechanical surface-sensing thermostat, liquid-filled capillary sensor, setpoint range -4°C to +163°C | 404385-000 | |
| T-M-10-S/0+50C | Mechanical line-sensing thermostat, setpoint range 0°C to +50°C | 105336-000 | No datasheetNo PDF |
| T-M-20-S/+0+200C/EX | Mechanical thermostat with limiter (0-200°C), Ex | 1244-013410 | No datasheetNo PDF |
| T-M-20-S/+50+300C/EX | Mechanical thermostat with limiter (50-300°C), Ex | 1244-013411 | No datasheetNo PDF |
| T-M-10-S/0+200C | Mechanical line-sensing thermostat, setpoint range 0°C to +200°C | 337388-000 | No datasheetNo PDF |
| T-M-10-S/+50+300C | Mechanical line-sensing thermostat, setpoint range +50°C to +300°C | 607672-000 | No datasheetNo PDF |
| T-M-20-S/0+100C | Mechanical line-sensing thermostat and limiter (0-100°C) | 1244-022642 | No datasheetNo PDF |
| T-M-20-S/0+200C | Mechanical line-sensing thermostat and limiter (0-200°C) | 1244-022643 | No datasheetNo PDF |
| T-M-20-S/+50+300C | Mechanical line-sensing thermostat and limiter (50-300°C) | 1244-022644 | No datasheetNo PDF |
What mechanical thermostats are used for
A mechanical thermostat is the simplest way to control a heating circuit: a liquid-filled sensor with a capillary measures the pipe temperature, and the thermostat contact switches the cable on or off directly. It needs no power for electronics and no programming, which makes it a good fit for single circuits used for frost protection and process temperature maintenance, including in hazardous areas. It works with BTV, QTVR and XTVR self-regulating heating cables and with VPL. Where an alarm, communication or multiple circuits are needed, electronic thermostats or controllers are a better choice.
Variants and designations
- RAYSTAT-EX-02 - EEx d thermostat with a 3 m capillary, set points from -4°C to +163°C, for hazardous areas.
- T-M-10-S/0+50C, T-M-10-S/0+200C, T-M-10-S/+50+300C - thermostats with pipe temperature sensing; the end of the designation gives the set point range.
- T-M-20-S/0+100C, T-M-20-S/0+200C, T-M-20-S/+50+300C - thermostat combined with a temperature limiter in one enclosure.
- T-M-20-S/+0+120C/EX, T-M-20-S/+0+200C/EX, T-M-20-S/+50+300C/EX - limiter versions approved for Ex areas (marked /EX).
RAYSTAT-EX-02 parameters
- SPDT changeover contact, 22 A at 480 V AC, 100,000 cycles.
- Hysteresis 5 K, repeatability ±1.7 K.
- SS316 stainless steel sensor, 3 m capillary, exposure temperature from -50°C to +215°C.
- Cast aluminium enclosure, 3/4" NPT entry, IP65 with GL-33 or GL-34 cable glands, operation from -40°C to +60°C, class T6, Zone 1, 2, 21 and 22.
Selection and installation
Switching the circuit directly limits its length: the RAYSTAT-EX-02 datasheet gives maximum cable lengths for circuit breakers up to 22 A, and at higher currents the thermostat must control a contactor. The thermostat is mounted on SB-100, SB-101, SB-110, SB-111 or SB-125 brackets or on a wall. We select the set point range, the limiter version and the cable glands, and then install the thermostats and set them during commissioning. Send us your parameters via the contact page.
Not sure which control system to choose?
Tell us how many circuits you need to supply and how control should work: thermostat, controller or integration with a DCS/BMS. We will select the controls and design the control panel.
Frequently asked questions
What is the difference between T-M-10-S and T-M-20-S?
+
T-M-10-S is a thermostat with pipe temperature sensing. T-M-20-S combines a thermostat with a temperature limiter, which also switches off the circuit once the limit set point is exceeded. Versions marked /EX are intended for hazardous areas.
Can RAYSTAT-EX-02 switch a heating cable directly?
+
Yes, for circuits protected up to 22 A, within the lengths given in the datasheet table. For circuit breakers above 22 A the thermostat cannot switch the circuit directly and controls a contactor instead.

















