❄️ Winter campaign: Protect installations against frost.See details

Replacements for discontinued Raychem products

Do you have a heating cable or control unit on site that can no longer be bought? On this page you will find equivalents for discontinued Raychem (Chemelex) products. We select the replacement, check its compatibility with the existing installation and - if necessary - replace or upgrade the heating circuit.

XTV → XTVR heating cables

The XTV series has been replaced by the XTVR series - self-regulating heating cables for higher process temperatures and hazardous areas. Equivalents are matched by rated output at +10°C; the final selection is confirmed by a pipe heat loss calculation.

Discontinued part number (XTV)Output at +10°CReplacement (XTVR)Output at +10°C
4XTV2-CT-T312 W/m3XTVR2-CT or 5XTVR2-CTno equivalent with the same output - selected after recalculating the heat loss9 W/m or 16 W/m
8XTV2-CT-T325 W/m8XTVR2-CT25 W/m
12XTV2-CT-T338 W/m12XTVR2-CT38 W/m
15XTV2-CT-T347 W/m15XTVR2-CT48 W/m
20XTV2-CT-T263 W/m20XTVR2-CT64 W/m

Other unavailable products - we will select a replacement

The products below are no longer available. The right replacement depends on the installation (temperatures, area classification, number of circuits, control method), so we select it individually.

How the replacement works

  1. Identification - part number, manufacturer's catalogue number or a photo of the rating plate, plus a description of the installation.
  2. Replacement selection - output, temperatures, Ex area, circuit lengths and accessory compatibility.
  3. Supply - Raychem heating cables, power connection kits and controls.
  4. Installation and commissioning - on-site replacement, testing and as-built documentation.

Frequently asked questions

What replaces XTV heating cable?

+

The XTV series has been succeeded by the XTVR series. For 8XTV2-CT-T3, 12XTV2-CT-T3, 15XTV2-CT-T3 and 20XTV2-CT-T2 the equivalent is the XTVR cable with the same (or practically the same) output at +10°C: 8XTVR2-CT, 12XTVR2-CT, 15XTVR2-CT and 20XTVR2-CT. For 4XTV2-CT-T3 we select 3XTVR2-CT or 5XTVR2-CT after recalculating the pipe heat loss.

Do the accessories need replacing when XTV is swapped for XTVR?

+

It depends on the condition and type of the connection kits on site. When replacing the cable, we always check that the power connection kits, end seals and controls are compatible with the new cable and meet the hazardous area requirements - and we supply any missing components.

My product is not on the list - what should I do?

+

Send us the part number, the manufacturer's catalogue number or a photo of the rating plate, together with a short description of the installation. We will select a current replacement from the Raychem (Chemelex) range and, if needed, prepare an upgrade of the whole heating circuit or its controls.

Send us the part number - we will find a replacement

Give us the part number or manufacturer's catalogue number of the discontinued product. We will reply with a matched equivalent and a quotation.