Photo coming soon
PI series heating cables - XPI-NH (non-hazardous areas)
PI series heating cables - XPI-NH (non-hazardous areas)
PI series heating cables - XPI-NH (non-hazardous areas) is a product line in the polymer insulated series resistance heating cables category. 36 variants are available. We will help you select the right type for your installation, prepare a quotation and take care of supply and installation.
36 variants in this line
Not sure which heating cable to choose?
Tell us about your installation: the medium, pipe diameter and length, maintain temperature and operating conditions. We will select the cable, output and installation method and, if needed, prepare the design.
Product types and technical specification
| Symbol | Description | Manufacturer no. | Datasheets |
|---|---|---|---|
| XPI-NH-8000Unavailable | PI series heating cable, 8000 Ω/km | 1244-003118 | |
| XPI-NH-7000Unavailable | PI series heating cable, 7000 Ω/km | 1244-003117 | |
| XPI-NH-5600Unavailable | PI series heating cable, 5600 Ω/km | 1244-003116 | |
| XPI-NH-5160Unavailable | PI series heating cable, 5160 Ω/km | 1244-003115 | |
| XPI-NH-4400Unavailable | PI series heating cable, 4400 Ω/km | 1244-003114 | |
| XPI-NH-4000Unavailable | PI series heating cable, 4000 Ω/km | 1244-003113 | |
| XPI-NH-3000Unavailable | PI series heating cable, 3000 Ω/km | 1244-003112 | |
| XPI-NH-2000Unavailable | PI series heating cable, 2000 Ω/km | 1244-003111 | |
| XPI-NH-1750Unavailable | PI series heating cable, 1750 Ω/km | 1244-003110 | |
| XPI-NH-1440Unavailable | PI series heating cable, 1440 Ω/km | 1244-003109 | |
| XPI-NH-1000Unavailable | PI series heating cable, 1000 Ω/km | 1244-003108 | |
| XPI-NH-810Unavailable | PI series heating cable, 810 Ω/km | 1244-003107 | |
| XPI-NH-700Unavailable | PI series heating cable, 700 Ω/km | 1244-003106 | |
| XPI-NH-600Unavailable | PI series heating cable, 600 Ω/km | 1244-003105 | |
| XPI-NH-480Unavailable | PI series heating cable, 480 Ω/km | 1244-003104 | |
| XPI-NH-380Unavailable | PI series heating cable, 380 Ω/km | 1244-003103 | |
| XPI-NH-320Unavailable | PI series heating cable, 320 Ω/km | 1244-003102 | |
| XPI-NH-200Unavailable | PI series heating cable, 200 Ω/km | 1244-003101 | |
| XPI-NH-180Unavailable | PI series heating cable, 180 Ω/km | 1244-003100 | |
| XPI-NH-150Unavailable | PI series heating cable, 150 Ω/km | 1244-003099 | |
| XPI-NH-100Unavailable | PI series heating cable, 100 Ω/km | 1244-003098 | |
| XPI-NH-80Unavailable | PI series heating cable, 80 Ω/km | 1244-003097 | |
| XPI-NH-65Unavailable | PI series heating cable, 65 Ω/km | 1244-003096 | |
| XPI-NH-50Unavailable | PI series heating cable, 50 Ω/km | 1244-003095 | |
| XPI-NH-31.5Unavailable | PI series heating cable, 31.5 Ω/km | 1244-003094 | |
| XPI-NH-25Unavailable | PI series heating cable, 25 Ω/km | 1244-003093 | |
| XPI-NH-17.8Unavailable | PI series heating cable, 17.8 Ω/km | 1244-003092 | |
| XPI-NH-15Unavailable | PI series heating cable, 15 Ω/km | 1244-003091 | |
| XPI-NH-11.7Unavailable | PI series heating cable, 11.7 Ω/km | 1244-003090 | |
| XPI-NH-10Unavailable | PI series heating cable, 10 Ω/km | 1244-003089 | |
| XPI-NH-7Unavailable | PI series heating cable, 7 Ω/km // PI cold lead, 2.5 mm², max. 32 A | 1244-003088 | |
| XPI-NH-4.4Unavailable | PI cold lead, 4 mm², max. 42 A | 1244-003087 | |
| XPI-NH-2.9Unavailable | PI series heating cable, 2.9 Ω/km // PI cold lead, 6 mm², max. 54 A | 1244-003086 | |
| XPI-NH-1.8Unavailable | PI series heating cable, 1.8 Ω/km // PI cold lead, 10 mm², max. 73 A | 1244-003085 | |
| XPI-NH-1.1Unavailable | PI series heating cable, 1.1 Ω/km // PI cold lead, 16 mm², max. 98 A | 1244-003084 | |
| XPI-NH-0.8Unavailable | PI cold lead, 25 mm², max. 129 A | 1244-003083 |
What XPI-NH is used for
XPI-NH is a polymer insulated (PI) series resistance heating cable intended only for non-hazardous areas. According to the datasheet, it was used for freeze protection and temperature maintenance of pipework, tanks and other equipment, particularly where the pipeline is longer than the maximum circuit length of parallel cables (the datasheet gives 250 m as an example).
The entire series is now marked as unavailable. We keep the data as a reference for existing installations where a circuit needs to be rebuilt or extended.
Construction and datasheet data
- PTFE inner insulation and outer jacket, nickel-plated copper protective braid (max. 18 Ω/km)
- max. exposure temperature 260°C (continuous, de-energised), min. installation temperature -60°C
- min. bending radius 2.5 x diameter at -25°C and 6 x diameter at -60°C
- max. heat output 25 W/m (typical value), rated voltage up to 300/500 V AC
- min. spacing between cables 20 mm
Variants and product codes
The number in the product code is the nominal resistance in Ω/km at 20°C: from XPI-NH-0.8 to XPI-NH-8000, with a tolerance of +10/-5%. For resistances below 31.5 Ω/km the datasheet recommends accounting for the change in resistance with temperature in calculations. As cold leads, the datasheet specifies the XPI range (from XPI-7 for 2.5 mm² to XPI-0.8 for 25 mm²), or alternatively XPI-S cold leads.
Replacement selection and installation service
We select a replacement for an XPI-NH circuit individually: we collect the resistance and length of the existing section, the supply voltage, the maintain temperature and the operating conditions, and then prepare a design and quotation. More about this process on the discontinued product replacements page. The datasheet requires protection with a 30 mA residual current device (max. 300 mA for higher leakage currents).
Send the circuit data via the contact form - we will prepare the selection, supply and installation.
Not sure which heating cable to choose?
Tell us about your installation: the medium, pipe diameter and length, maintain temperature and operating conditions. We will select the cable, output and installation method and, if needed, prepare the design.
Frequently asked questions
Can XPI-NH cables still be ordered?
+
The XPI-NH series is marked as unavailable. We select a replacement individually after analysing the data of the existing circuit, not by simply substituting a product code.
What does the number in the XPI-NH product code mean?
+
It is the cable's nominal resistance in Ω/km at 20°C, e.g. XPI-NH-100 has 100 Ω/km. Together with the circuit length and voltage, it determines the output per metre.
What circuit protection does the XPI-NH datasheet require?
+
The datasheet requires a 30 mA residual current device, and for designs with higher leakage current allows a maximum of 300 mA after all safety aspects have been checked.