Spare parts is a product line in the installation materials (tapes, bands, clamps, other) category. 27 variants are available, including JBS-SPA, JBM-SPA, JBS-100-STANDOFF, JBM-100-STANDOFF, E-100-BOOT-5/PACK, T-100-CRIMP-KIT, HWA-WAGO-TSTAT-KIT, HWA-WAGO-PHASE. We will help you select the right type for your installation, prepare a quotation and take care of supply and installation.
27 variants in this line
Not sure which accessories you need?
Tell us which cable you are installing and on what: pipework, a tank or a surface. We will advise which tapes, bands, brackets and labels you need, and in what quantities.
Product types and technical specification
| Symbol | Description | Manufacturer no. | Datasheets |
|---|---|---|---|
| JBS-SPA | Adapter for mounting JBS-100, E-100 and E-100-L on small pipe diameters (5 pcs) | E90515-000 | No datasheetNo PDF |
| JBM-SPA | Small pipe diameter adapter for JBM-100, T-100 | D55673-000 | No datasheetNo PDF |
| JBS-100-STANDOFF | Standoff for single-entry junction box | P000003408 | No datasheetNo PDF |
| JBM-100-STANDOFF | Standoff for multiple-entry junction box | P000003624 | No datasheetNo PDF |
| E-100-BOOT-5/PACK | Spare insulating caps for the E-100-E kit | 281053-000 | No datasheetNo PDF |
| T-100-CRIMP-KIT | Set of spare crimp sleeves for the T-100 kit | 577853-000 | No datasheetNo PDF |
| HWA-WAGO-TSTAT-KIT | Additional terminals for connecting a thermostat to JBS/JBM-100 boxes, includes 2 WAGO 284 terminals and one GL-36-M25 cable gland | 966659-000 | No datasheetNo PDF |
| HWA-WAGO-PHASE | Additional WAGO 284 series terminals (10mm²) for phase/neutral conductor | 633476-000 | No datasheetNo PDF |
| HWA-WAGO-EARTH | Additional WAGO 284 series terminals (10mm²) for protective earth conductor | 911505-000 | No datasheetNo PDF |
| HWA-WAGO-ENDPLATE | Additional end plates for WAGO 284 series terminals | 983674-000 | No datasheetNo PDF |
| HWA-WAGO-JUMPER | Additional jumpers for bridging WAGO 284 series terminals | 550942-000 | No datasheetNo PDF |
| HWA-WDM-PHASE-16 | Phase/neutral terminal 16mm², Weidmuller type, ATEX | 1244-006991 | No datasheetNo PDF |
| HWA-WDM-PHASE-35 | Phase/neutral terminal 35mm², Weidmuller type, ATEX | 1244-006990 | No datasheetNo PDF |
| HWA-WDM-EARTH-10 | Earth terminal 10mm², Weidmuller type, ATEX | 1244-006994 | No datasheetNo PDF |
| HWA-WDM-EARTH-16 | Earth terminal 16mm², Weidmuller type, ATEX | 1244-006993 | No datasheetNo PDF |
| HWA-WDM-EARTH-35 | Earth terminal 35mm², Weidmuller type, ATEX | 1244-006992 | No datasheetNo PDF |
| HWA-WDM-PLATE | Weidmuller end plate for WDU type terminals | 1244-007004 | No datasheetNo PDF |
| HWA-WDM-JUMPER-16-2 | Terminal jumper for two Weidmuller 16mm² terminals | 1244-006997 | No datasheetNo PDF |
| HWA-WDM-JUMPER-16-3 | Terminal jumper for three Weidmuller 16mm² terminals | 1244-006998 | No datasheetNo PDF |
| HWA-WDM-JUMPER-16-4 | Terminal jumper for four Weidmuller 16mm² terminals | 1244-006999 | No datasheetNo PDF |
| HWA-WDM-JUMPER-35-2 | Terminal jumper for two Weidmuller 35mm² terminals | 1244-006995 | No datasheetNo PDF |
| HWA-WDM-JUMPER-35-3 | Terminal jumper for three Weidmuller 35mm² terminals | 1244-006996 | No datasheetNo PDF |
| SM-PT100-1 | Sensor module for PT100 sensor - 1 terminal for Raystat V5 controller | 1244-022441 | No datasheetNo PDF |
| SM-PT100-2 | Sensor module for 2 PT100 sensors - 2 terminals for ELEXANT 450c | 1244-022442 | No datasheetNo PDF |
| HARD-69 | Temperature sensor for AT-TS-13 and AT-TS-14 thermostats | 133571-000 | No datasheetNo PDF |
| HARD-78 | Spare temperature sensor for RAYSTAT-CONTROL-10 thermostat | 213430-000 | No datasheetNo PDF |
| HARD-79 | Temperature sensor for RAYSTAT-ECO-10 | 651224-000 | No datasheetNo PDF |
What spare parts are used for
This line covers items that let you repair, extend or adapt existing accessories without replacing the whole kit. It includes adapters and standoffs for junction boxes, spare boots and crimps for end seal kits, additional WAGO and Weidmuller terminals, PT100 sensor modules and spare thermostat sensors. They are a natural complement to junction boxes and connection kits when servicing an installation.
Variants and designations
- Junction box mounting: JBS-SPA (small pipe adapter for JBS-100, E-100 and E-100-L, 5 pcs), JBM-SPA (for JBM-100 and T-100), JBS-100-STANDOFF and JBM-100-STANDOFF standoffs
- Kits: E-100-BOOT-5/PACK - spare insulating boots for E-100-E, T-100-CRIMP-KIT - crimp sleeves for T-100
- WAGO 284 series terminals (10 mm²): HWA-WAGO-PHASE, HWA-WAGO-EARTH, HWA-WAGO-ENDPLATE end plates, HWA-WAGO-JUMPER jumpers and HWA-WAGO-TSTAT-KIT (2 terminals and a GL-36-M25 gland for connecting a thermostat in JBS/JBM-100)
- Weidmuller ATEX terminals: phase HWA-WDM-PHASE-16/-35, earth HWA-WDM-EARTH-10/-16/-35, HWA-WDM-PLATE plate, HWA-WDM-JUMPER-16-2/-3/-4 and -35-2/-3 jumpers
- Measurement: SM-PT100-1 (Raystat V5), SM-PT100-2 (2 PT100 sensors, ELEXANT 450c), sensors HARD-69 (AT-TS-13, AT-TS-14), HARD-78 (RAYSTAT-CONTROL-10), HARD-79 (RAYSTAT-ECO-10)
Selection and service
We identify a spare part by the symbol of the device it will be used in and, for terminals, by the conductor cross-section. During installation inspections we replace damaged items on site, and we match sensors to the specific thermostat or temperature controller model. Send us the device symbol via the contact page and we will check the matching part.
Not sure which accessories you need?
Tell us which cable you are installing and on what: pipework, a tank or a surface. We will advise which tapes, bands, brackets and labels you need, and in what quantities.
Frequently asked questions
Which spare sensor fits RAYSTAT-ECO-10?
+
The HARD-79 sensor is intended for RAYSTAT-ECO-10, HARD-78 for RAYSTAT-CONTROL-10, and HARD-69 for AT-TS-13 and AT-TS-14 thermostats.
How do I add a thermostat to a JBS-100 or JBM-100 box?
+
Use HWA-WAGO-TSTAT-KIT: two additional WAGO 284 series terminals and a GL-36-M25 cable gland.
Are the Weidmuller terminals in this line ATEX approved?
+
Yes, the HWA-WDM-PHASE-16 and -35 phase terminals and the HWA-WDM-EARTH-10, -16 and -35 earth terminals are described as ATEX.