❄️ Winter campaign: Protect installations against frost.See details
Cable glands, adapters, reducers

Cable glands, adapters, reducers

Cable glands, adapters, reducers is a product line in the cable glands, adapters, reducers category. 20 variants are available, including ADPT-M20/25-EEXD, GL-33, GL-34, GL-36-M25, ADPT-PG16/M25-EEXE, GL-38-M25-METAL, GL-45-M32, GL-51-M40. We will help you select the right type for your installation, prepare a quotation and take care of supply and installation.

20 variants in this line

Not sure which connections and end seals to choose?

Give us the heating cable type, the number of circuits and the installation conditions, including hazardous areas. We will put together kits, junction boxes and glands that work together.

Help me choose the components

Product types and technical specification

SymbolDescriptionManufacturer no.Datasheets
ADPT-M20/25-EEXDAdapter M20/M25 (Ex)684953-000No PDF
GL-33Cable gland (armoured cables) for RAYSTAT-EX-02, ATEX1244-017517No PDF
GL-34Cable gland (unarmoured cables) for RAYSTAT-EX-02, ATEX1244-017518No PDF
GL-36-M25Cable gland M25 (8-17mm), ATEX774424-000No PDF
ADPT-PG16/M25-EEXEAdapter PG16/M25 (Ex, cable outer diameter up to 15 mm)541892-000No PDF
GL-36-M25Cable gland M25 (8-17mm) for JBS-100, JBM-100, JBU-100 boxes, ATEX1244-019082No PDF
GL-38-M25-METALCable gland M25 (8-17mm) for JBS-100, JBM-100, JBU-100 boxes, ATEX056622-000No PDF
GL-45-M32Cable gland M32 (Ex)1244-000847No PDF
GL-51-M40Power cable gland M40, polyamide, ATEX1244-007003No PDF
GL-61-M25Power cable gland M25, polyamide, ATEX2000004034No PDF
GL-62-M25Power cable gland M25, polyamide, ATEX2000004033No PDF
HWA-PLUG-M20-EXE-PLASTICBlanking plug M20, ATEX1244-000845No PDF
HWA-PLUG-M25-EXE-PLASTICBlanking plug M25, ATEX434994-000No PDF
REDUCER-1NPT/M25Stainless steel reducer 1’’NPT to M25, hazardous area (Ex d)1244-000953No PDF
REDUCER-M25/20Reducer M25/M20 (ATEX) with washer and locknut630617-000No PDF
REDUCER-M25/20-EEXDReducer M25/M20 (Ex)404287-000No PDF
REDUCER-M25/M20-PAReducer M25/M20 (non-hazardous area)184856-000No PDF
REDUCER-M25/PG16-EEXEReducer M25/PG16 (Ex, cable outer diameter up to 13 mm)953780-000No PDF
REDUCER-M32/M25-EEXEReducer M32/M25 (Ex)1244-000859No PDF
REDUCER-M40/M32-EEXEReducer M40 (male) to M32 (female), polyamide, ATEX1244-007007No PDF

What cable glands, adapters and reducers are used for

These are small components on which the sealing and Ex approval of the whole connection point depend. The cable gland brings the supply cable into the junction box or thermostat, the reducer and adapter match the gland thread to the enclosure entry, and the blanking plug closes an unused entry. Most items carry ATEX or Ex marking. REDUCER-M25/M20-PA is intended for non-hazardous areas.

Variants and product codes

  • GL-36-M25 and GL-38-M25-METAL - M25 cable glands (8-17 mm) for JBS-100, JBM-100 and JBU-100 junction boxes, ATEX
  • GL-33 (armoured cables) and GL-34 (unarmoured cables) - cable glands for RAYSTAT-EX-02, ATEX
  • GL-45-M32 - M32 cable gland (Ex), GL-51-M40, GL-61-M25, GL-62-M25 - polyamide supply cable glands, ATEX
  • REDUCER-M25/20-EEXD (Ex d), REDUCER-M25/20 (ATEX, with washer and locknut), REDUCER-M32/M25-EEXE, REDUCER-M40/M32-EEXE (polyamide, ATEX)
  • REDUCER-M25/PG16-EEXE - reducer for cables up to 13 mm, REDUCER-1NPT/M25 - stainless steel, 1" NPT to M25, Ex d
  • ADPT-M20/25-EEXD - M20/M25 adapter (Ex), ADPT-PG16/M25-EEXE - PG16/M25 adapter for cables up to 15 mm
  • HWA-PLUG-M20-EXE-PLASTIC and HWA-PLUG-M25-EXE-PLASTIC - M20 and M25 blanking plugs, ATEX

Selection and installation

We match four things: the thread of the enclosure entry, the outer diameter of the cable, the cable type (armoured or not) and the enclosure's type of protection, because an Ex d component cannot replace an Ex e one and vice versa. We supply cable glands together with junction boxes and connection kits, so that the power point is ready for installation. Send us the list of enclosures and cables via contact.

Not sure which connections and end seals to choose?

Give us the heating cable type, the number of circuits and the installation conditions, including hazardous areas. We will put together kits, junction boxes and glands that work together.

Help me choose the components

Frequently asked questions

Which cable gland fits JBS-100 and JBM-100 junction boxes?

+

According to the product descriptions, M25 cable glands for 8-17 mm cables are intended for JBS-100, JBM-100 and JBU-100 junction boxes: GL-36-M25 and the metal GL-38-M25-METAL.

What is the difference between an Ex d and an Ex e reducer?

+

They are different types of explosion protection for the enclosure. The component must match the device's type of protection, so for example we use REDUCER-M25/20-EEXD with Ex d equipment and REDUCER-M32/M25-EEXE with Ex e.

Are there components for non-hazardous areas?

+

Yes, REDUCER-M25/M20-PA is an M25/M20 reducer intended for non-hazardous areas.