Cable glands, adapters, reducers
Cable glands, adapters, reducers is a product line in the cable glands, adapters, reducers category. 20 variants are available, including ADPT-M20/25-EEXD, GL-33, GL-34, GL-36-M25, ADPT-PG16/M25-EEXE, GL-38-M25-METAL, GL-45-M32, GL-51-M40. We will help you select the right type for your installation, prepare a quotation and take care of supply and installation.
20 variants in this line
Not sure which connections and end seals to choose?
Give us the heating cable type, the number of circuits and the installation conditions, including hazardous areas. We will put together kits, junction boxes and glands that work together.
Product types and technical specification
| Symbol | Description | Manufacturer no. | Datasheets |
|---|---|---|---|
| ADPT-M20/25-EEXD | Adapter M20/M25 (Ex) | 684953-000 | No datasheetNo PDF |
| GL-33 | Cable gland (armoured cables) for RAYSTAT-EX-02, ATEX | 1244-017517 | No datasheetNo PDF |
| GL-34 | Cable gland (unarmoured cables) for RAYSTAT-EX-02, ATEX | 1244-017518 | No datasheetNo PDF |
| GL-36-M25 | Cable gland M25 (8-17mm), ATEX | 774424-000 | No datasheetNo PDF |
| ADPT-PG16/M25-EEXE | Adapter PG16/M25 (Ex, cable outer diameter up to 15 mm) | 541892-000 | No datasheetNo PDF |
| GL-36-M25 | Cable gland M25 (8-17mm) for JBS-100, JBM-100, JBU-100 boxes, ATEX | 1244-019082 | No datasheetNo PDF |
| GL-38-M25-METAL | Cable gland M25 (8-17mm) for JBS-100, JBM-100, JBU-100 boxes, ATEX | 056622-000 | No datasheetNo PDF |
| GL-45-M32 | Cable gland M32 (Ex) | 1244-000847 | No datasheetNo PDF |
| GL-51-M40 | Power cable gland M40, polyamide, ATEX | 1244-007003 | No datasheetNo PDF |
| GL-61-M25 | Power cable gland M25, polyamide, ATEX | 2000004034 | No datasheetNo PDF |
| GL-62-M25 | Power cable gland M25, polyamide, ATEX | 2000004033 | No datasheetNo PDF |
| HWA-PLUG-M20-EXE-PLASTIC | Blanking plug M20, ATEX | 1244-000845 | No datasheetNo PDF |
| HWA-PLUG-M25-EXE-PLASTIC | Blanking plug M25, ATEX | 434994-000 | No datasheetNo PDF |
| REDUCER-1NPT/M25 | Stainless steel reducer 1’’NPT to M25, hazardous area (Ex d) | 1244-000953 | No datasheetNo PDF |
| REDUCER-M25/20 | Reducer M25/M20 (ATEX) with washer and locknut | 630617-000 | No datasheetNo PDF |
| REDUCER-M25/20-EEXD | Reducer M25/M20 (Ex) | 404287-000 | No datasheetNo PDF |
| REDUCER-M25/M20-PA | Reducer M25/M20 (non-hazardous area) | 184856-000 | No datasheetNo PDF |
| REDUCER-M25/PG16-EEXE | Reducer M25/PG16 (Ex, cable outer diameter up to 13 mm) | 953780-000 | No datasheetNo PDF |
| REDUCER-M32/M25-EEXE | Reducer M32/M25 (Ex) | 1244-000859 | No datasheetNo PDF |
| REDUCER-M40/M32-EEXE | Reducer M40 (male) to M32 (female), polyamide, ATEX | 1244-007007 | No datasheetNo PDF |
What cable glands, adapters and reducers are used for
These are small components on which the sealing and Ex approval of the whole connection point depend. The cable gland brings the supply cable into the junction box or thermostat, the reducer and adapter match the gland thread to the enclosure entry, and the blanking plug closes an unused entry. Most items carry ATEX or Ex marking. REDUCER-M25/M20-PA is intended for non-hazardous areas.
Variants and product codes
- GL-36-M25 and GL-38-M25-METAL - M25 cable glands (8-17 mm) for JBS-100, JBM-100 and JBU-100 junction boxes, ATEX
- GL-33 (armoured cables) and GL-34 (unarmoured cables) - cable glands for RAYSTAT-EX-02, ATEX
- GL-45-M32 - M32 cable gland (Ex), GL-51-M40, GL-61-M25, GL-62-M25 - polyamide supply cable glands, ATEX
- REDUCER-M25/20-EEXD (Ex d), REDUCER-M25/20 (ATEX, with washer and locknut), REDUCER-M32/M25-EEXE, REDUCER-M40/M32-EEXE (polyamide, ATEX)
- REDUCER-M25/PG16-EEXE - reducer for cables up to 13 mm, REDUCER-1NPT/M25 - stainless steel, 1" NPT to M25, Ex d
- ADPT-M20/25-EEXD - M20/M25 adapter (Ex), ADPT-PG16/M25-EEXE - PG16/M25 adapter for cables up to 15 mm
- HWA-PLUG-M20-EXE-PLASTIC and HWA-PLUG-M25-EXE-PLASTIC - M20 and M25 blanking plugs, ATEX
Selection and installation
We match four things: the thread of the enclosure entry, the outer diameter of the cable, the cable type (armoured or not) and the enclosure's type of protection, because an Ex d component cannot replace an Ex e one and vice versa. We supply cable glands together with junction boxes and connection kits, so that the power point is ready for installation. Send us the list of enclosures and cables via contact.
Not sure which connections and end seals to choose?
Give us the heating cable type, the number of circuits and the installation conditions, including hazardous areas. We will put together kits, junction boxes and glands that work together.
Frequently asked questions
Which cable gland fits JBS-100 and JBM-100 junction boxes?
+
According to the product descriptions, M25 cable glands for 8-17 mm cables are intended for JBS-100, JBM-100 and JBU-100 junction boxes: GL-36-M25 and the metal GL-38-M25-METAL.
What is the difference between an Ex d and an Ex e reducer?
+
They are different types of explosion protection for the enclosure. The component must match the device's type of protection, so for example we use REDUCER-M25/20-EEXD with Ex d equipment and REDUCER-M32/M25-EEXE with Ex e.
Are there components for non-hazardous areas?
+
Yes, REDUCER-M25/M20-PA is an M25/M20 reducer intended for non-hazardous areas.